Thông số kỹ thuật nguồn Meanwell ENP-180-48
![Nguồn Meanwell ENP-180-48](https://gialuctech.com/wp-content/uploads/2023/12/z4944745630323_4c2addb71528f7f6fc06d2d9c13e1246-300x167.jpg)
![Nguồn Meanwell ENP-180-48](https://gialuctech.com/wp-content/uploads/2023/12/z4879817259380_270519c8653248f28d6951fb523ed92c-225x300.jpg)
MODEL | ENP-180-12 | ENP-180-24 | ENP-180-48 | ||
OUTPUT |
DC VOLTAGE | 13.8V | 27.6V | 55.2V | |
RATED CURRENT | 13A | 6.5A | 3.3A | ||
CURRENT |
RATED | 0 ~ 13A | 0 ~ 6.5A | 0 ~ 3.3A | |
PEAK Note.2 | 16.3A | 8.1A | 4.1A | ||
WATTAGE |
RATED | 179W | 179W | 182W | |
PEAK Note.2 | 225W | 224W | 226W | ||
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | 150mVp-p | 350mVp-p | ||
VOLTAGE ADJ. RANGE | 11.5 ~ 15V | 23.5 ~ 30V | 47.5 ~ 58.8V | ||
VOLTAGE TOLERANCE Note.4 | ±1.0% | ±1.0% | ±1.0% | ||
LINE REGULATION Note.5 | ±0.5% | ±0.5% | ±0.5% | ||
LOAD REGULATION Note.6 | ±2.0% | ±1.0% | ±0.5% | ||
SETUP, RISE TIME Note.7 | 1000ms, 100ms at full load | ||||
HOLD UP TIME (Typ.) | 20ms at full load | ||||
INPUT |
VOLTAGE RANGE Note.8 | 90 ~ 264VAC 127 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC at full load | ||||
EFFICIENCY (Typ.) | 91% | 93.5% | 94% | ||
AC CURRENT (Typ.) | 1.9A/115VAC 0.95A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 70A at 230VAC | ||||
LEAKAGE CURRENT | <3.5mA / 240VAC | ||||
NO LOAD POWER CONSUMPTION | <0.15W | ||||
PROTECTION |
SHORT CIRCUIT | Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||
OVERLOAD |
Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with auto-recovery after the peak load condition is removed | ||||
Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed | |||||
OVER VOLTAGE |
15.5 ~ 18.2V | 31 ~ 36.5V | 62.1 ~ 72.9V | ||
Protection type : Shut down o/p voltage, re-power on to recover | |||||
OVER TEMPERATURE | Shut down O/P voltage, recovers automatically after temperature goes down | ||||
ENVIRONMENT |
WORKING TEMP. | -30 ~ +70℃ (Refer to “Derating Curve”) | |||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||
TEMP. COEFFICIENT | ±0.05%/℃ (0 ~ 50℃) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
SAFETY & EMC (Note 9) |
SAFETY STANDARDS | IEC60950-1, UL60950-1, EAC TP TC 004 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||
EMC EMISSION |
Parameter | Standard | Test Level / Note | ||
Conducted | EN55032 (CISPR32) / FCC PART15 (CISPR22) | Class B | |||
Radiated | EN55032 (CISPR32) / FCC PART15 (CISPR22) | Class B | |||
Harmonic Current | EN61000-3-2 | —– | |||
Voltage Flicker | EN61000-3-3 | —– | |||
EMC IMMUNITY |
EN55024 | ||||
Parameter | Standard | Test Level / Note | |||
ESD | EN61000-4-2 | Level 3, 8KV air ; Level 2, 4KV contact | |||
Radiated | EN61000-4-3 | Level 2, 3V/m | |||
EFT / Burst | EN61000-4-4 | Level 2, 1KV | |||
Surge | EN61000-4-5 | Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth | |||
Conducted | EN61000-4-6 | Level 2, 3Vrms | |||
Magnetic Field | EN61000-4-8 | Level 1, 1A/m | |||
Voltage Dips and Interruptions | EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods |
|||
OTHERS |
MTBF | 170.6K hrs min. MIL-HDBK-217F (25℃) | |||
DIMENSION | 192*178*45.5mm (L*W*H) | ||||
PACKING | 1.15Kg; 10pcs/12.5Kg /1.34CUFT | ||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Peak current or peak power up to 3 seconds is provided. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. Line regulation is measured from low line to high line at rated load. 6. Load regulation is measured from 0% to 100% rated load. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 8. Derating may be needed under low input voltages. Please check the derating curve for more details. 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft}. |
Tên gọi khác Nguồn tổ ong Meanwell ENP-180-48
- Bộ nguồn dạng tĩnh ENP-180-48
- Bộ chuyển nguồn điện ENP-180-48
- Nguồn Meanwell ENP-180-48
- Bộ nguồn Meanwell ENP-180-48
- Bộ chuyển đổi nguồn điện ENP-180-48
- Bộ chuyển đổi điện ENP-180-48
- Bộ chuyển đổi nguồn ENP-180-48
- cục đổi nguồn ENP-180-48
- Nguồn tổ ong ENP-180-48
- Nguồn tổng AC-DC ENP-180-24
- Switching Power Supply ENP-180-48
Thông tin liên hệ:
MEAN WELL ENTERPRISES CO., LTD
Trung tâm chiến lược sản phẩm
Mọi chi tiết xin liên hệ:
➤Địa chỉ:
Chi nhánh 1: (Nhật Tảo)
149 Nhật Tảo, Phường 08, Quận 10, Thành phố Hồ Chí Minh, Việt Nam
Chi nhánh 2: (Văn Chung)
20 Văn Chung, Phường 13, Quận Tân Bình, Thành phố Hồ Chí Minh
Số điện thoại liên lạc:
MST: 0317302151
Hotline: 0946 954 220
Kinh doanh: 0903 684 220
Email: GiaLucTech@gmail.com
Website: www.gialuctech.com – meanwell.net.vn – www.meanwellchinhhang.com
Đánh giá
Chưa có đánh giá nào.